Model NO.: IRW-2001
Classification: Infant Radiant Warmer
Applications: Nicu,Operating Room
Phototherapy Unit: LED
Information: Can Be Stored
Modes: Pre-Warm ,Manual or Automatic
Oxygen Cylinder: Yes
Vertical Height: Electric Adjusted
Tilt Angle of Bed: Stepless Adjustable
Heater Head: Adjusted
Silicon mattress: Yes
Trademark: Perlong
Transport Package: Carton
Specification: with trolley
Origin: China
HS Code: 90189090
Model NO.: IRW-2001
Classification: Infant Radiant Warmer
Applications: Nicu,Operating Room
Phototherapy Unit: LED
Information: Can Be Stored
Modes: Pre-Warm ,Manual or Automatic
Oxygen Cylinder: Yes
Vertical Height: Electric Adjusted
Tilt Angle of Bed: Stepless Adjustable
Heater Head: Adjusted
Silicon mattress: Yes
Trademark: Perlong
Transport Package: Carton
Specification: with trolley
Origin: China
HS Code: 90189090
 Resuscitaire Neonatal  Infant Radiant Warmer With Infant Head Fixing Unit
Brief Introduction:
Three control modes: Pre-warm mode control, manual mode control and baby mode control by micro-computer;
The information can be stored, consulted and indicated by the LCD display screen;
Failure alarm indication;
The angle of warmer module is adjustable horizontally;
Inclination of the bassinet is adjustable;
The panels around bassinet can be turned outward;
Silicon mattress is heatable and temperature is controllable;
With LED phototherapy function;
APGAR timer;
Vertical height adjustment (VHA) stand;
Disposable skin temperature sensor is optional.
Standard Configuration:
Main body (including the warmer module, controller, bassinet, main column and VHA stand), skin temperature sensor, I.V. Pole, mattress, tray and panels.
Specification:
Power requirement: Â AC220V-230V/50Hz or AC110-120V/50-60Hz, 900VA
Mode of control: Pre-warm mode, manual mode and baby mode are controlled by micro-computer
Baby mode temperature control range: 34.5-37.5ºC
Control accuracy:   ≤0.5ºC
Accuracy of skin temperature sensor:  ±0.2ºC
Temperature uniformity of mattress:   ≤2ºC
Mattress heating control range: 25-38ºC
Accuracy of mattress temperature display: ±0.7ºC
Angle of warmer module: ±60° , radiant heating focus on the mattress
Inclination of bassinet: The Max. angle on trendelenburg is 15°, on reverse trendelenburg is 20°
APGAR timer: audible and visible alarm when the device runs to 50″~1′, 4′50″~5′, 9′50″~10′;
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on.
Max. bilirubin radiation on the mattress effective range: ≥1mW/cm2Â
Average value general bilirubin radiation of on the mattress effective range: ≥0.8mW/cm2Â
Bilirubin uniformity of radiating on the mattress effective range: >0.4
Â
 Resuscitaire Neonatal  Infant Radiant Warmer With Infant Head Fixing Unit
Brief Introduction:
Three control modes: Pre-warm mode control, manual mode control and baby mode control by micro-computer;
The information can be stored, consulted and indicated by the LCD display screen;
Failure alarm indication;
The angle of warmer module is adjustable horizontally;
Inclination of the bassinet is adjustable;
The panels around bassinet can be turned outward;
Silicon mattress is heatable and temperature is controllable;
With LED phototherapy function;
APGAR timer;
Vertical height adjustment (VHA) stand;
Disposable skin temperature sensor is optional.
Standard Configuration:
Main body (including the warmer module, controller, bassinet, main column and VHA stand), skin temperature sensor, I.V. Pole, mattress, tray and panels.
Specification:
Power requirement: Â AC220V-230V/50Hz or AC110-120V/50-60Hz, 900VA
Mode of control: Pre-warm mode, manual mode and baby mode are controlled by micro-computer
Baby mode temperature control range: 34.5-37.5ºC
Control accuracy:   ≤0.5ºC
Accuracy of skin temperature sensor:  ±0.2ºC
Temperature uniformity of mattress:   ≤2ºC
Mattress heating control range: 25-38ºC
Accuracy of mattress temperature display: ±0.7ºC
Angle of warmer module: ±60° , radiant heating focus on the mattress
Inclination of bassinet: The Max. angle on trendelenburg is 15°, on reverse trendelenburg is 20°
APGAR timer: audible and visible alarm when the device runs to 50″~1′, 4′50″~5′, 9′50″~10′;
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on.
Max. bilirubin radiation on the mattress effective range: ≥1mW/cm2Â
Average value general bilirubin radiation of on the mattress effective range: ≥0.8mW/cm2Â
Bilirubin uniformity of radiating on the mattress effective range: >0.4
Â