The enzyme-linked immunosorbent kit is based on the principle of double antibody sandwich technology to detect human lactoferrin (LF), which can only be used for research purposes and should not be used for medical diagnosis. Uses : For the determination of lactoferrin (LF) in human serum, plasma and related liquid samples.
Working principle <br> This kit uses biotin double antibody sandwich enzyme-linked immunosorbent assay (ELISA) to determine human lactoferrin (LF) levels in samples. Human lactoferrin (LF) was added to the well-labeled wells pre-coated with human lactoferrin (LF) monoclonal antibody, and incubated; after incubation, biotin-labeled anti-lactoferrin (LF) antibody was added. It is then combined with streptavidin-HRP to form an immune complex, which is then incubated and washed to remove unbound enzymes, then added to substrates A and B to produce a blue color, which is converted to a final form by acid. Yellow. The color depth is positively correlated with the concentration of human lactoferrin (LF) in the sample.
Kit composition Kit composition | 48-hole configuration | 96-well configuration | save |
Instruction manual | 1 serving | 1 serving | |
Sealing film | 2 pieces (48) | 2 pieces (96) | |
sealed bag | 1 | 1 | |
Enzyme label coated plate | 1×48 | 1×96 | 2-8 ° C preservation |
Standard 240μg/ml | 0.5ml × 1 bottle | 0.5ml × 1 bottle | 2-8 ° C preservation |
Standard dilution | 3ml × 1 bottle | 6ml × 1 bottle | 2-8 ° C preservation |
Streptavidin-HRP | 3 ml × 1 bottle | 6 ml × 1 bottle | 2-8 ° C preservation |
Biotinylated anti-LF antibody | 0.5ml × 1 bottle | 1 ml × 1 bottle | 2-8 ° C preservation |
Developer A solution | 3 ml × 1 bottle | 6 ml × 1 bottle | 2-8 ° C preservation |
Developer B solution | 3 ml × 1 bottle | 6 ml × 1 bottle | 2-8 ° C preservation |
Stop solution | 3ml × 1 bottle | 6ml × 1 bottle | 2-8 ° C preservation |
Concentrated washing solution | (20ml × 20 times) × 1 bottle | (20ml × 30 times) × 1 bottle | 2-8 ° C preservation |
Reagents and equipment that are not provided - 37 ° C incubator.
- Standard specification microplate reader.
- Precision pipettes and disposable tips
- Distilled water,
- Disposable test tube
- Absorbent paper
Precautions - The kit removed from 2-8 ° C should be equilibrated at room temperature for at least 30 minutes before opening the kit. If the enzyme label is not used up after the plate is opened, the slats should be stored in a sealed bag.
- The sampler should be used for each step, and the accuracy should be corrected frequently to avoid test error.
- Strictly follow the instructions of the manual, the test results must be based on the microplate reader reading.
- To avoid cross-contamination, avoid reusing the tips and closures in your hand.
- Other reagents that are not used should be packaged or covered. Do not mix reagents of different batches. Use before warranty.
- Substrate B is sensitive to light and avoids prolonged exposure to light.
Washing method Manual washing method: smash the liquid in the microplate; pour a few layers of absorbent paper on the test bench, and take a few times with the microplate; use at least 0.35ml of the diluted washing solution into the hole, soak 1 2 minutes. Repeat this process several times as needed.
Automatic washing: If there is an automatic washing machine, it should be used in the formal experiment after skilled use.
Specimen requirements 1. Samples containing NaN3 could not be detected because NaN3 inhibited horseradish peroxidase (HRP) activity.
2. The specimens should be extracted as soon as possible after collection, and the extraction should be carried out according to the relevant literature. The experiment should be carried out as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 °C, but repeated freezing and thawing should be avoided.
Operating procedure - Dilution of standard: (This kit provides one original standard, which can be diluted in a small tube according to the following chart.)
120μg/ml | Standard No. 5 | Add 120 μl of standard dilution to 120 μl of standard dilution |
60μg/ml | Standard No. 4 | Add 120 μl of Standard No. 5 to 120 μl of Standard Diluent |
30μg/ml | Standard No. 3 | Add 120 μl of Standard No. 4 to 120 μl of Standard Diluent |
15μg/ml | Standard 2 | Add 120 μl of Standard No. 3 to 120 μl of Standard Diluent |
7.5μg/ml | Standard No. 1 | Add 120 μl of Standard 2 to 120 μl of Standard Diluent |
- The number of slats required is determined by the number of samples taken and the number of standards. Multiple holes are recommended for each standard and blank hole. Each sample is determined according to its own quantity, and the double hole can be used as much as possible.
- Loading: 1) blank well, blank control well without sample, biotinylated anti-LF antibody, streptavidin-HRP, only coloring agent A&B and stop solution, the other steps are the same ; 2) standard Pinhole : Add standard 50ul, streptavidin-HRP50ul (the biotin antibody has been integrated in the standard, so it is not added ); 3) Substitute sample well: add 40ul sample , then add anti-LF antibody 10ul Streptavidin-HRP50ul , covered with a sealing membrane, gently shake and mix, incubate at 37 ° C for 60 minutes.
- Solution: 30 times concentrated washing solution was diluted with distilled water 30 times and used.
- Washing: Carefully remove the sealing film, discard the liquid, dry it, fill each well with the washing solution, let stand for 30 seconds, then discard it, repeat 5 times, and pat dry.
- Color development: Add A50ul of coloring agent to each well, then add 50μl of coloring agent, gently shake and mix, and develop color at 37°C for 15 minutes.
- Termination: 50 μl of stop solution was added to each well to terminate the reaction (in this case, the blue color turned yellow).
- Measurement: The absorbance (OD value) of each well was measured in sequence with a blank air conditioner of zero and a wavelength of 450 nm. The measurement should be carried out within 10 minutes after the addition of the stop solution.
- The linear regression equation of the standard curve is calculated according to the concentration of the standard product and the corresponding OD value, and the corresponding sample concentration is calculated on the regression equation according to the OD value of the sample. It can also be calculated using various application software.
Summary of operating procedures:
Kit performance: 1. The linear regression coefficient of the sample and the expected concentration correlation coefficient R value is 0.92 or more.
2. Within and between batches should be less than 9% and 15% respectively
examination range: Detection range: 5μg/ml -130μg/ml
Storage conditions and expiration date: Storage: 2-8 ° C.
Validity: 6 months (2-8 ° C).