Seat belt testing equipment use and precautions

Safety belt detection equipment use precautions

Article from Qingdao Zhongbang Instrument Co., Ltd. Technology Department

The seat belt testing equipment is the important test equipment for the safety belt manufacturer's quality control, LA safety mark certification and industrial production license evaluation, as well as the construction engineering inspection unit and the labor insurance station inspection qualification review. The most important equipment is ZD-715 seat belt. Overall dynamic load static load tester, ZD-717 seat belt overall slip tester, ZW-737 salt spray test chamber and ZD-718 seat belt tensile tester. The seat belt testing equipment is different from the general testing equipment. Since the seat belt testing equipment mostly simulates the actual use environment and state test, the required test site is relatively large, and the professional level of the experimenter is required to be relatively high, and the safety awareness is relatively strong. The safe operation rules must be strictly observed in the use of the project. The following are the precautions for the use of these devices:

1. ZD-715 seat belt overall dynamic load, static load testing machine

1. Non-professional maintenance personnel are not allowed to open the cover and disassemble and change the electrical components inside the instrument.

2. In case of emergency, please press the emergency stop button quickly and cut off the main power supply. After the fault is removed, turn it on again.

3. The power supply of the instrument is a single-phase AC power supply, and there must be a reliable grounding wire.

4. When the instrument is not used for a long time or encounters rain or snow, you need to remove the dynamic sensor. The removal step is: the person must climb to the corresponding height while wearing the seat belt, remove the plastic parts, remove the sensor with a wrench, and remove the corresponding connecting line.

5. When the instrument is not used for a long time or encounters rain or snow weather, it is necessary to properly protect the instrument components. For example, the box with the motor is covered with a tarpaulin to prevent rainwater from entering the inside of the box along the hole at the top, causing damage to the motor. The controller of the electric lifting device needs to be wrapped with a tarpaulin to prevent rainwater from entering and the like.

6. The flat sling in the accessory is used for the secondary protection of the seat belt. When the test belt is unqualified, the flat sling can only be subjected to three impacts. When testing again, the flat sling must be replaced.

7. In all test procedures, as long as the simulator is off the bottom surface, the tester must be away from the shelf for more than 3m, whether during lifting or release. Prevent accidental injuries from falling objects. One minute after the completion of the test, the person can enter the internal position of the frame to handle the follow-up.

9. In the static load test, because the test force value is relatively large, in order to prevent the personal injury caused by the ejection of the sample when the sample breaks, the safety net is hung on the side of the shelf where the tester operates.

10 , be sure to match the UPS uninterruptible power supply matching the instrument (otherwise, in the unstable power supply state, the simulated person has the danger of falling!), in the case of emergency power failure, quickly turn the selector switch to "keep the suction" Status, then turn off the instrument. When the power supply is normal, lower the simulator, then turn the selector switch to the "test state" and restart the test.

Second, ZD-717 seat belt overall slip tester

1. The instrument must be fixed with anchor bolts.

2. The column must be fixed during the test.

3. Adjust the flap during the test so that the column is located in the groove of the flap.

Third, seat belt tension machine

1. The instrument has two display windows. The first window displays the sensor force value in N; the second window displays the countdown time in seconds.

2. Before starting the test, please warm up for 15 minutes.

3. When the instrument is running, please do not put the head and hands close to the chuck and moving parts to avoid injury.

4 , non-professional maintenance personnel are not allowed to open the cover to disassemble and change the electrical components inside the instrument.

5. In case of emergency, please press the emergency stop button quickly and cut off the main power supply. After the fault is removed, turn it on again.

6. The power supply of the instrument is a single-phase AC power supply, and there must be a reliable grounding wire.

7. The dynamic test part of the instrument is equipped with upper (lower) limit stroke protection. When the loading device runs to the upper (lower) limit position, it plays a protective role. At this time, you need to press "reset" ("start") or pass "Dropping" ("Dropping") drops (rises) the loading device a distance.

8. The “Reset” button on the operation panel can only be used after the end of one test, that is, the indicator light flashes and the beep is 10s, and the “clear” button should be used to stop the test.

This article is the original article of Qingdao Zhongbang Instrument Co., Ltd. If you need to reprint, you must add the source of the description, and you will be responsible for reprinting without permission.

Frozen Squid Tentacles

Frozen squid tentacles are the arms or tentacles of a squid that have been frozen for preservation. Squid tentacles are commonly used in cooking and are popular in many cuisines around the world. They can be grilled, fried, sautéed, or used in soups and stews. Frozen squid tentacles are convenient to use as they can be stored in the freezer for an extended period and can be thawed and cooked as needed. They are also a good source of protein and low in fat, making them a healthy addition to any meal.