Rat (Rat) pepsin (PP) ELISA test kit instruction manual
Detection principle
The kit uses a double antibody one-step sandwich enzyme-linked immunosorbent assay (ELISA). The coated microcapsules of the pepsin (PP) antibody were pre-coated, and the specimen, the standard, and the HRP-labeled detection antibody were sequentially added, and the cells were washed and thoroughly washed. Using the substrate TMB to develop color, TMB is converted to blue under the catalysis of peroxidase and converted to the final yellow color by the action of an acid. The color depth is positively correlated with pepsin (PP) in the sample. The absorbance (OD value) was measured at 450 nm using a microplate reader to calculate the sample concentration.
Sample collection, processing and storage methods
1. Serum: Use a tube containing no pyrogen and endotoxin. Avoid any cell irritation during the procedure. After collecting the blood, centrifuge and centrifuge for 10 minutes at 3000 rpm to quickly and carefully separate the serum and red blood cells.
2. Plasma: EDTA, citrate or heparin anticoagulation. The supernatant was taken by centrifugation at 3000 rpm for 30 minutes.
3. Cell supernatant: Centrifuge at 3000 rpm for 10 minutes to remove particles and polymer.
4. Tissue homogenization: The tissue is mashed by adding appropriate amount of physiological saline. The supernatant was taken by centrifugation at 3000 rpm for 10 minutes.
5. Storage: If the sample is not detected in time after collection, please dispense it once, freeze it at -20 °C, avoid repeated freezing and thawing, thaw at room temperature and ensure that the sample is fully thawed evenly.
Bring your own items
Operational precautions
Kit composition
name | 96-well configuration | 48 hole configuration | Remarks |
Microporous ELISA plate | 12 holes × 8 | 12 holes × 4 | no |
Standard | 0.3mL*6 tube | 0.3mL*6 tube | no |
Sample diluent | 6mL | 3mL | no |
Detection antibody-HRP | 10mL | 5mL | no |
20× washing buffer | 25mL | 15mL | Dilute according to the instructions |
Substrate A | 6mL | 3mL | no |
Substrate B | 6mL | 3mL | no |
Stop solution | 6mL | 3mL | no |
Sealing film | 2 sheets | 2 sheets | no |
Instruction manual | 1 copy | 1 copy | no |
Ziplock bag | 1 | 1 | no |
Note: The concentration of standard (S0-S5) is: 0, 3, 6, 12, 24, 48 ng/mL
Reagent preparation
Dilution of 20× Wash Buffer: Distilled water was diluted 1:20, ie 1 part of 20× Wash Buffer plus 19 parts of distilled water.
Washing method
Steps
Result judgment
Draw a standard curve: In the Excel worksheet, the standard concentration is used as the abscissa, and the OD value is plotted as the ordinate. The linear regression curve of the standard is drawn, and the concentration values ​​of each sample are calculated according to the curve equation.
Kit performance
Disclaimer
Shanghai Yuduo Biotechnology Co., Ltd. produces and sells elisa kit, animal serum, plasma, whole blood, antigen and antibody, gold standard kit test card, antiserum, biological reagents, culture medium, laboratory equipment consumables, chemical reagents, biological products. , standard products, reference products, biochemical immunological products, immunoaffinity columns, strains, plasmids, indoor quality control products, cells, ice packs, agent imported products, etc.
Contact Phone Contact QQ
Large favorably! Welcome dealers to discuss cooperation matters!
Positive Pressure Fire Air Breathing Apparatus
All connections on the pipeline can be freely rotated 360 degrees, which is suitable for the needs of various occasions.
With high temperature resistance, flame retardant, insulation, anti-corrosion, waterproof, light weight, good air tightness and other properties.
Positive pressure fire air breathing apparatus,selfcontained air breathing apparatus,fire air breathing apparatus
joho(HK) Technology Co. , Ltd. , https://www.joho-safety.com