Indoor gas environment (TVOC) detection dedicated gas chromatograph configuration scheme

Indoor air detection (five items) instrument configuration

The main source of total volatile organic compounds, TVOC, is outdoor, mainly from fuel combustion and transportation: indoors are mainly from combustion products such as coal and natural gas, smoke from smoking, heating and cooking, construction and decorative materials, furniture, Household appliances, detergents and emissions from the body itself. There are nearly a thousand. In the interior decoration process, VOC is mainly from paints, coatings and adhesives. It is reported that the indoor TVOC concentration is usually between 0.2mg/m3 and 2mg/m3, and even in the improper decoration construction, it can even be dozens of times higher. Many indoor aromatic hydrocarbons and alkanes are mainly derived from automobile exhaust (76%-92%). The typical paint towel TVOC content is 0.4-1. mg / cubic meter. Li Li et al pointed out that because TVOC has strong volatility, in general, 90% of the paint can be volatilized within 10 hours after the construction, while the TVOC in the solvent only releases 25% of the total amount in the paint drying process. Since benzene and benzene are important components of TVOC, some people only detect TVOC, not benzene, and benzene: however, only total benzene is detected, not TVOC: there are some units, both Detection. This mainly depends on the requirements and conditions. The technical equipment for detecting TVOC is relatively high, and gas chromatography is usually used, but Fourier transform infrared spectroscopy, fluorescence spectroscopy, ion chromatography and reflection interference spectroscopy are also used. They all appear at trace levels and trace levels and are therefore easily overlooked. They are mainly from: organic solutions: such as paints, aqueous coatings, adhesives, cosmetics, detergents, quilting; building materials: such as wood-based panels, foam insulation, plastic sheets; interior materials: such as wallpaper, other Decorations, etc.; fiber materials: such as carpets, tapestries and chemical fiber curtains; incomplete combustion of household fuels and tobacco leaves, human waste. The detection principle of TVOC is to collect a certain volume of air sample with TenaxTA as the adsorbent TVOC adsorption tube, and the volatile organic compounds in the air stream remain in the adsorption tube. After sampling, the adsorption tube is heated to absorb volatile organic compounds, and the sample to be tested enters the capillary gas chromatograph with an inert carrier gas. After capillary separation under certain conditions, FID detection, workstation recording spectra and data, qualitative time, peak height or peak area quantitation.

Indoor gas environment (TVOC) detection dedicated gas chromatograph configuration scheme:

equipment name
Models and Specifications
unit
Quantity
Gas Chromatograph (optional)
Host + FID + filling system + capillary system
station
1
Host + FID + filling system
Host + FID + capillary system
station
2
Chromatography workstation
TVOC dedicated version Dual channel
station
1
Air generator
HS-3 0~3000ml/min
station
1
Hydrogen generator
HS-300 0~300ml/min 99.999%
station
1
nitrogen bottle
High purity nitrogen 99.999% with pressure reducing valve
set
1
Thermal desorber
ATDS-6000 direct injection
station
1
Multifunctional desorbent activation device
TDS-3410A desorber activation and standard sample and sample machine
station
1
Spectrophotometer
Detection of formaldehyde and ammonia
station
1
Measuring instrument
Continuous measurement
station
1
Dual gas path atmospheric sampler (optional)
0.1~1.5L/min; continuous adjustable timing: 1~99min
station
1
Constant current sampling flow: 0.4~0.6L/min
station
1
Constant current working flow range: 100~500ml/min
station
1
Empty box pressure gauge
Pressure gauge
station
1
thermometer
Temperature and humidity
station
1
Digital blast drying oven
350×350×350
station
1
Quartz double distilled water meter
Ammonia free
station
1
Electronic balance
Accuracy: 0.1mg; weighing range: 200g
station
1
Sample box
Packing equipment such as absorption tube and sampling tube; equipped with aluminum alloy bracket
One
1
TVOC dedicated column
0.32mm*50m*1u
support
1
Benzene special column
3mm*2M
support
1
Tenax adsorption tube
200mg 50pcs/box (quantity optional)
box
1
Activated carbon sampling tube
50 sticks/package (quantity optional)
package
1
Bubble absorber
10ml (optional)
support
1
Glass plate absorber
10ml (optional)
support
1
TVOC standard
10, 100, 1000ug/ml
set
1
Benzene standard solution
2ml
support
1
Benzene standard gas
2L 5 component
bottle
1
Phenol reagent
5g
bottle
1
Formaldehyde solution
20ml 100mg/L or 2ml 10.2mg/ml
support
1
Ammonia solution
20ml 500mg/L
support
1